About SEDA Policies Net Metering Feed-in Tariff (FiT) Statistics & Monitoring Download & Media Directory Events & Trainings
ANNOUNCEMENTS
Reinstatement of Fees for Testing & Commissioning Witnessing for Solar PV under the Community Category   22/06/2018
Continuous Development Programme (CDP) for SEDA Malaysia Grid-Connected Solar PV Systems Design Qualified Persons (QPs)   25/04/2018
Guideline on Solar Photovoltaic Installation under Net Energy Metering (NEM) Scheme, 8th February 2018.   16/03/2018
Seminar on Energy Audit Conditional Grant (Commercial & Industry) under the RMK-11   15/02/2018
Sebut Harga SEDA(SH)-01/2018:Tawaran Sebut Harga bagi Merekabentuk, Menterjemah, Mencetak dan Membekal Laporan Tahunan 2017 bagi SEDA Malaysia   05/02/2018
NEW TRAINING COURSE: "Operation & Maintenance of Biogas Power Plant Course"   14/12/2017
Guidelines for Eligibility of the S02 Bonus – “Use as Building Material” for Solar PV Applications under the Feed-in Tariff (FiT) Mechanism   06/12/2017
SEDA (SH) 09/ 2017 - Perolehan Hijau: Tawaran Sebut Harga Membekal, Menghantar, Memasang, Menguji, Mentauliah dan Menyelenggara Perkakasan ICT untuk SEDA Malaysia   30/10/2017


Home  »  Announcements


Guideline on Solar Photovoltaic Installation under Net Energy Metering (NEM) Scheme, 8th February 2018.
 

The amendment shown below as approved by Suruhanjaya Tenaga (ST) at its meeting on 8th February 2018 to the Guidelines of Solar Photovoltaic Installation on Net Energy Metering (NEM).

The amendment has been carried out between clause 17, 18, 25 and 36 (vii) (d) of the Guidelines, and shown in bold hereunder:-

  1. For commercial and industrial consumers, the maximum capacity of the PV system installed shall be:

a) 1MWp or 75% of maximum demand of the consumer’s current installation (for current transformer metering), whichever is lower;

  1. based on the past 1 year average of the recorded maximum demand of the consumer’s installation;
  2. the declared maximum demand for consumers with less than 1 year;

b) 60% of fuse rating (for direct meter) or 60% of current transformer (CT) rating for low voltage consumers.

  1. The permissible net export capacity for connection to the distribution system shall be not less than 1kWp and not more than 1MWp rating measured at the connection point,

Provided that the net export capacity at the Connection Point shall not exceed 75% of the maximum demand of the energy metering consumer.

  1. The requirement for a mandatory study is generally based on the rated kWp of the proposed installation as shown in Table 1:

Table 1: Requirement for a mandatory study based on kWp of installation.

* For installation more than 1MWp, the fee for Power System Study may applies.

  1. vii)  The documents to be submitted by the Applicant shall include:

                   (d)  NEM Assessment Study (for application > 12kWp 72kWp);

 

SEDA Malaysia, 16th March 2018.

 